Quick answer: an electric furnace makes heat with resistance elements, so there is no gas, igniter or flue. When it fails, the cause is usually a burned-out element, a failed sequencer or relay, a tripped limit switch, or a breaker and wiring fault. Call (773) 514 3683, tell us whether the blower runs and whether the air is warm, and we test the circuit before quoting any part.
Symptom, likely cause, first check
Blower runs, air is cold: element, sequencer, relay or limit switch. Check the filter and registers first, because a limit that trips on restricted airflow looks like a dead element. Nothing runs: breaker, disconnect, transformer, door switch or thermostat. Breaker keeps tripping: a shorted element or loose connection; do not keep resetting it. Warm but weak heat: one of several elements has failed, so the furnace still runs but produces less heat.
What we measure
We check supply voltage at the furnace, current draw on each element, continuity of each element, the sequencer or relays that stage the elements on one after another, the limit switches and the blower. Electric furnaces draw a lot of current, so loose lugs and a tired breaker matter as much as the heating parts.
Electric heat in older Chicago housing
Many furnaces in older Chicago homes run on gas, so an electric furnace is more often found in a converted unit, an addition, an apartment or a small commercial space. The median home in ZIP 60634 was built in 1952 (ACS 2020-2024), and the age of the wiring and panel matters because of the current involved.
What you can safely do
Replace the filter, check the thermostat is on heat, and look at the breaker. If it has tripped, reset it once. Do not open panels with power on. Turn the furnace breaker off before anyone touches the unit.
When to call
Call (773) 514 3683 when the furnace is cold, the breaker trips again, you smell burning plastic or wiring, or you see scorch marks. If you smell burning and see smoke, turn the breaker off and leave the home; call 911 for fire.
Next steps
After testing we explain the failed part, the fix and the price in writing, and we do not replace anything until you approve it.
Technician insight
In Chicago 60634 the thing that catches most people out with Electric Furnace Repair is the original aluminum wiring in pre-1970 bungalows around Irving Park. Homeowners replace the element only to have the connection melt again because the panel and branch wiring were never checked for proper torque and oxidation.
No Heat During January Cold Snap
A 1962 bungalow near 6947 W Irving Park Rd lost heat when two elements shorted. We found melted sequencer contacts and oxidized aluminum wiring at the disconnect. Replaced the elements and sequencer, torqued all connections to spec, and confirmed limit switch operation before restoring power.
Electric Furnace Repair Services We Offer
✓Heating Element Replacement
Test each element for continuity and current draw, and replace only the one that has failed.
✓Sequencer and Relay Repair
Replace the controls that stage the elements on when the blower runs but heat never arrives.
✓Limit Switch and Airflow Diagnosis
Find why the furnace overheats and shuts off, usually a clogged filter, weak blower or closed registers.
✓Breaker and Connection Checks
Tighten and test lugs and connections and check that the breaker matches the furnace load.
Electric Furnace Repair Cost in Chicago 60634, IL
| Service | Typical Range | What Affects It |
|---|---|---|
| Heating Element Replacement | $180–$350 | Price varies by number of elements and access in older homes |
| Blower Motor Replacement | $300–$550 | Includes capacitor; higher for multi-speed units in tight closets |
| Control Board Or Sequencer Repair | $220–$420 | Depends on whether board is rebuilt or replaced |
| Full Electrical Inspection And Tightening | $150–$275 | Required on homes with original aluminum wiring |
Ranges are typical for Chicago 60634, IL and confirmed with an exact written quote before any work starts.
How it works
- 1
Call and describe
Tell us whether the blower runs, whether any air is warm and whether a breaker has tripped.
- 2
Electrical testing
We test power at the furnace, the elements, sequencer, relays and limit switch.
- 3
Written quote
You see the failed part, the fix and the price before any replacement.
- 4
Repair and test
We run a full heating call and confirm temperature rise and amp draw are in range.
Pricing
We give a written quote after testing; the price depends on which element, relay or control failed.