Quick answer: if the furnace runs but your home stays cold, check three things first: thermostat set to heat, a clean filter and open registers. If those are fine, call (773) 514 3683 and tell us whether the burners light and whether the air from the vents is warm. That answer sorts most causes.
Furnace runs, heat is weak
Weak heat usually means restricted airflow (clogged filter, closed or blocked registers, blocked return), a furnace short on gas input, a failing limit or a thermostat that is off calibration. If the furnace runs constantly but never catches up, the system may be undersized or the ducts leaking, which is common in older houses.
Symptom, likely cause, first check
Warm air but house never reaches setpoint: dirty filter, closed registers, blocked return or leaking ducts. Lukewarm air: weak flame or a gas input problem. Only some rooms cold: duct, damper or register issue in that run. Heat arrives only for a minute: limit tripping on poor airflow. We measure temperature rise across the furnace to tell weak output from duct loss.
What you can safely do
Replace the filter, open every register and make sure the return grille is not blocked by boxes or furniture, which is common in finished basements. Check the thermostat is on heat with a setpoint above the room temperature.
Cold rooms versus no heat
If the whole house is cold and the burners do not fire, see our no-start and ignition pages. This page covers a furnace that runs but does not deliver enough heat.
Chicago housing context
With a median build year of 1952 and many two-flats in ZIP 60634 (ACS 2020-2024), duct runs have often been modified over decades, which can leave rooms with poor airflow. Chicago's January normal low at O'Hare is 18.8 F (NWS 1991-2020), enough that a weak furnace never catches up.
When to call
If those checks do not fix it, call (773) 514 3683. If you smell gas, leave and call Peoples Gas at 866-556-6002.
Technician insight
In Chicago 60634 the thing that catches most people out with Furnace Not Heating is restricted return air from finished basement ceilings. The original ductwork in Irving Park two-flats was never sized for the extra rooms added later, so the furnace overheats and trips the limit before homeowners notice low airflow.
Irving Park Two-Flat No Heat Call
Homeowner reported the furnace running but no warm air. We found the return grille in the finished basement blocked by stored boxes and a tripped limit switch. After clearing the grille and resetting the switch, temperature rise returned to spec and the system stayed online through the next cold front.
Furnace Not Heating Services We Offer
✓Airflow Diagnosis
Check filter, blower, registers, return and accessible ducts for restrictions.
✓Thermostat and Control Testing
Confirm the thermostat is calling and the furnace is responding.
✓Temperature-rise and Burner Check
Measure how much the furnace heats the air and check the flame to see if it is producing full heat.
Furnace Not Heating Cost in Chicago 60634, IL
| Service | Typical Range | What Affects It |
|---|---|---|
| Thermostat replacement | $180–$320 | Depends on smart vs standard model and wiring access in older homes |
| Hot surface igniter | $220–$380 | Includes part and labor; higher on 90%+ furnaces with limited cabinet access |
| Blower motor service | $350–$650 | ECM motors cost more; PSC units are lower |
| Pressure switch replacement | $190–$290 | Includes vent inspection |
Ranges are typical for Chicago 60634, IL and confirmed with an exact written quote before any work starts.
How it works
- 1
Check the basics
Thermostat, filter, registers and breaker.
- 2
Measure temperature rise
We measure how much the furnace heats the air to find under-performance.
- 3
Written quote
You see the fix and cost before work.
- 4
Verify
We re-measure after the repair.
Pricing
We give a written quote after on-site diagnosis, before any work starts.