Quick answer: if the furnace will not start at all, with no click, no fan and no light, the problem is usually power or a safety switch: a tripped breaker, an off switch, a loose door switch, a dead transformer or a thermostat issue. Work through the checks below, then call (773) 514 3683.
Checks you can do safely
- Thermostat on heat, setpoint above room temperature, fresh batteries if it uses them. 2. The furnace switch (it looks like a light switch near the unit) is on. 3. The breaker or fuse has not tripped; reset once. 4. The blower door or front panel is seated, because it presses the door switch that allows startup. 5. On a high-efficiency furnace, a condensate or float switch can stop startup if the drain is backed up.
Symptom, likely cause
Completely dead, status light off: no power to the furnace (breaker, switch, door switch or transformer). Status light on, no response to thermostat: thermostat, wiring or control board. Light blinking: a fault code; the legend is inside the door. Fan runs, nothing else: the safety chain or ignition; see our ignition page. Clicking: ignition issue.
What we test
We test line voltage at the furnace, the 24-volt transformer, the control board, the door switch and the thermostat wires, and we trace the safety chain (limit, rollout and pressure switches) if the board has power but nothing follows.
Related problems
Clicking without flame is an ignition problem; see our ignition page. A furnace that starts and then stops is covered by our shutting-off page.
When to stop
If you smell gas leave and call Peoples Gas at 866-556-6002. If the breaker trips repeatedly or you smell burning, stop and call. Call (773) 514 3683 and tell us what the status light does.
Technician insight
In Chicago 60634, the thing that catches most people out with Furnace Won't Turn On is the combination of 60-year-old wiring and tight basement access around Irving Park Road—homeowners often replace the thermostat first when the real issue is a tripped rollout switch from restricted return air in the original gravity ducts.
Bungalow on the 6900 block of W Irving Park
Homeowner reported the furnace silent after a cold snap. Inspection showed the rollout switch open due to a partially blocked flue shared with the upstairs unit. Cleared the vent, replaced the switch, and verified proper draft before restoring heat.
Furnace Won't Turn On Services We Offer
✓Power and Breaker Diagnosis
Trace power loss to the furnace from the breaker to the switch and disconnect.
✓Transformer and Control Board Testing
Test the low-voltage side that tells the furnace to start.
✓Door, Rollout and Float Switch Repair
Replace safety switches that block startup, and find out why they opened.
Furnace Won't Turn On Cost in Chicago 60634, IL
| Service | Typical Range | What Affects It |
|---|---|---|
| Diagnostic visit | $99–$150 | Includes testing of power, thermostat, and safety switches |
| Igniter replacement | $180–$320 | Parts and labor; varies by furnace model |
| Limit or rollout switch | $140–$260 | Depends on access and whether venting needs clearing |
| Transformer replacement | $160–$280 | Includes wiring inspection in older homes |
Ranges are typical for Chicago 60634, IL and confirmed with an exact written quote before any work starts.
How it works
- 1
Confirm power
Breaker, switch and voltage at the unit.
- 2
Test low-voltage
Transformer, thermostat and board.
- 3
Written quote
Price before parts.
- 4
Test startup
Full cycle.
Pricing