Quick answer: a furnace that starts and then shuts itself off, and may refuse to restart, is protecting itself. Usual triggers are a dirty flame sensor (shuts off within seconds), overheating from restricted airflow (shuts off after minutes) or a venting problem. Call (773) 514 3683 and tell us how long it runs before it stops.
How long it runs tells us the cause
Seconds, burners light then go out: flame sensor or gas valve. A few minutes, then a click and silence: high-limit trip from a clogged filter, closed registers or failing blower. Starts the draft inducer but never lights: pressure switch, blocked vent or condensate drain. Cycles all day without finishing: see our short cycling page.
Lockout
Many furnaces lock out after repeated failed starts. Resetting once is fine. If it locks out again, the fault is still there, and repeated resets can stress parts and let unburned gas collect.
What you can safely do
Replace the filter, open all registers and check that the thermostat is on heat. On a high-efficiency furnace with white PVC pipes, check the outside vent and intake terminations for snow, ice or debris and clear them if you can reach them safely without a ladder.
Venting and condensate
High-efficiency furnaces use PVC vent pipes and a condensate drain; a blocked vent or drain can shut them off. A pressure switch proves venting before the burners fire.
Weather
Snow and ice over exterior vent and intake pipes is a realistic cause in a Chicago winter; Chicago's January normal low at O'Hare is 18.8 F (NWS 1991-2020).
Safety
If you smell gas, leave and call Peoples Gas at 866-556-6002; for CO leave and call 911. Otherwise call (773) 514 3683.
Technician insight
In Chicago 60634 the thing that catches most people out with Furnace Keeps Shutting Off is snow or leaves blocking the inducer vent on the north side of brick bungalows along Irving Park Road; the pressure switch trips even though the furnace itself is fine, and homeowners keep resetting the board until the inducer fails.
Irving Park Bungalow Shutdown
A 1952 bungalow near 6947 W Irving Park Rd lost heat every evening when temperatures dropped below 20°F. We found the inducer vent partially blocked by drifted snow and a dirty flame sensor. After clearing the vent and cleaning the sensor the furnace completed full cycles without lockout.
Furnace Keeps Shutting Off Services We Offer
✓Flame Sensor Service
Clean or replace the sensor that proves the flame.
✓Overheat and Limit Diagnosis
Find airflow restrictions that trip the high limit.
✓Venting, Condensate and Pressure Switch Check
Test the vent, intake, drain and the pressure switch.
Furnace Keeps Shutting Off Cost in Chicago 60634, IL
| Service | Typical Range | What Affects It |
|---|---|---|
| Diagnostic Visit | $95–$150 | Includes error code pull and safety checks; credited if repair performed same day. |
| Flame Sensor Cleaning | $120–$200 | Price rises if sensor needs replacement. |
| High Limit Switch Replacement | $180–$320 | Varies by model access in tight 60634 basements. |
| Inducer Motor Replacement | $350–$650 | Includes pressure switch test; higher for two-stage units. |
Ranges are typical for Chicago 60634, IL and confirmed with an exact written quote before any work starts.
How it works
- 1
Time the shutdown
How long it runs points to the cause.
- 2
Test
Sensor, limit, pressure switch.
- 3
Written quote
Price before work.
- 4
Run cycles
Confirm it stays on.
Pricing
We give a written quote after on-site inspection, before work starts.