Furnace Blowing Cold Air in Chicago, IL

Cold air from the vents while the thermostat calls for heat: the burners are probably not staying lit.

  • ✓Owner-operated
  • ✓Shop on W Irving Park Rd
  • ✓Gas and electric furnaces

Quick answer: if cold air blows from the vents when the furnace is supposed to be heating, the blower is running but the burners are off. The usual causes are a flame that will not stay lit, a furnace in lockout, an overheating limit trip, or a thermostat fan switch set to ON. Call (773) 514 3683.

Check the fan setting first

If the thermostat fan is set to ON, the blower runs between heat cycles and blows room-temperature air. Set it to AUTO and see if warm air arrives during a heat call.

Symptom, likely cause, first check

Cold air the whole time: burners never light (ignition, gas supply, lockout). Warm for a minute, then cold: limit switch tripping from poor airflow, or flame sensor shutting the gas off. Cold air only at start-up: normal for a short delay while the heat exchanger warms; a few seconds to a minute is normal. Cold air and clicking: igniter or gas valve.

What you can safely do

Set the fan to AUTO, replace the filter, make sure registers are open and look at the furnace's status light, which blinks a fault code on many furnaces; the code is printed inside the door. Write down the code when you call.

Burners are not staying lit

If air is cold during a heat call, look at the furnace. Does it try to light? A flame that goes out after a few seconds points to the flame sensor. No flame at all points to ignition or gas supply. Cold air after a short warm start points to an overheating limit or poor airflow.

Furnace types

This page is for gas furnaces. If you have an electric furnace or a heat pump the causes differ; tell us which when you call.

Safety

If you smell gas, leave and call Peoples Gas at 866-556-6002. For carbon monoxide leave and call 911.

Call us

Call (773) 514 3683 and tell us what the burners do and whether a status light is blinking.

Technician insight

In Chicago 60634 the thing that catches most people out with a furnace blowing cold air is an original 1950s limit switch mounted in a finished basement return that has never been replaced; once the switch sticks open the blower keeps running on cool air even though the burners never light.

Dunning Bungalow Cold-Air Call

Homeowner in a 1948 brick bungalow near Narragansett and Irving Park reported the furnace running continuously yet blowing room-temperature air. We found the sail switch stuck from years of basement dust and confirmed the igniter was still functional. After replacing the switch and cleaning the sensor, the furnace completed a normal heat cycle and maintained 72 degrees through the next cold snap.

Furnace Blowing Cold Air Services We Offer

✓Flame Sensor Service

Clean or replace a sensor that shuts the burners off.

✓Limit Switch and Airflow Diagnosis

Find why the furnace overheats and cycles off.

✓Lockout and Fault-code Diagnosis

Read the status light code and find why the control board locked out.

Furnace Blowing Cold Air Cost in Chicago 60634, IL

Service Typical Range What Affects It
Diagnostic visit $99–$150 Includes combustion test; credited toward repair if work is approved same day
Igniter or flame sensor replacement $180–$320 Parts and labor; varies by furnace brand and access
Limit or sail switch replacement $160–$280 Includes testing of related wiring
Blower capacitor or belt service $140–$250 Motor inspection included; motor replacement quoted separately

Ranges are typical for Chicago 60634, IL and confirmed with an exact written quote before any work starts.

How it works

  1. 1

    Check fan setting

    Rule out the simple thermostat setting.

  2. 2

    Watch burner cycle

    See whether the burners light and stay lit.

  3. 3

    Written quote

    Price in writing before work.

  4. 4

    Test

    Confirm warm air at the vents.

Pricing

We give a written quote after inspection, before any work starts.

Furnace Craft Co — Furnace Repair in Chicago 60634

Good to know

Furnace Blowing Cold Air — FAQs

Still have questions? We're happy to talk it through.

(773) 514 3683
+ Why is my furnace blowing cold air?
The burners are not lit. A flame sensor, ignition fault, lockout or overheat trip is the usual cause.
+ Could it be the thermostat?
Yes. A fan set to ON or a bad thermostat can cause it. We check this first.
+ Is cold air at start-up normal?
A short delay is normal. Cold air that continues is not.
+ What does the blinking light mean?
Many furnaces blink a fault code. The legend is on the inside of the door; tell us the code when you call.
+ Is it dangerous?
Cold air is not itself dangerous, but a gas smell or CO alarm means leave and call Peoples Gas or 911.