Quick answer: if cold air blows from the vents when the furnace is supposed to be heating, the blower is running but the burners are off. The usual causes are a flame that will not stay lit, a furnace in lockout, an overheating limit trip, or a thermostat fan switch set to ON. Call (773) 514 3683.
Check the fan setting first
If the thermostat fan is set to ON, the blower runs between heat cycles and blows room-temperature air. Set it to AUTO and see if warm air arrives during a heat call.
Symptom, likely cause, first check
Cold air the whole time: burners never light (ignition, gas supply, lockout). Warm for a minute, then cold: limit switch tripping from poor airflow, or flame sensor shutting the gas off. Cold air only at start-up: normal for a short delay while the heat exchanger warms; a few seconds to a minute is normal. Cold air and clicking: igniter or gas valve.
What you can safely do
Set the fan to AUTO, replace the filter, make sure registers are open and look at the furnace's status light, which blinks a fault code on many furnaces; the code is printed inside the door. Write down the code when you call.
Burners are not staying lit
If air is cold during a heat call, look at the furnace. Does it try to light? A flame that goes out after a few seconds points to the flame sensor. No flame at all points to ignition or gas supply. Cold air after a short warm start points to an overheating limit or poor airflow.
Furnace types
This page is for gas furnaces. If you have an electric furnace or a heat pump the causes differ; tell us which when you call.
Safety
If you smell gas, leave and call Peoples Gas at 866-556-6002. For carbon monoxide leave and call 911.
Call us
Call (773) 514 3683 and tell us what the burners do and whether a status light is blinking.
Technician insight
In Chicago 60634 the thing that catches most people out with a furnace blowing cold air is an original 1950s limit switch mounted in a finished basement return that has never been replaced; once the switch sticks open the blower keeps running on cool air even though the burners never light.
Dunning Bungalow Cold-Air Call
Homeowner in a 1948 brick bungalow near Narragansett and Irving Park reported the furnace running continuously yet blowing room-temperature air. We found the sail switch stuck from years of basement dust and confirmed the igniter was still functional. After replacing the switch and cleaning the sensor, the furnace completed a normal heat cycle and maintained 72 degrees through the next cold snap.
Furnace Blowing Cold Air Services We Offer
✓Flame Sensor Service
Clean or replace a sensor that shuts the burners off.
✓Limit Switch and Airflow Diagnosis
Find why the furnace overheats and cycles off.
✓Lockout and Fault-code Diagnosis
Read the status light code and find why the control board locked out.
Furnace Blowing Cold Air Cost in Chicago 60634, IL
| Service | Typical Range | What Affects It |
|---|---|---|
| Diagnostic visit | $99–$150 | Includes combustion test; credited toward repair if work is approved same day |
| Igniter or flame sensor replacement | $180–$320 | Parts and labor; varies by furnace brand and access |
| Limit or sail switch replacement | $160–$280 | Includes testing of related wiring |
| Blower capacitor or belt service | $140–$250 | Motor inspection included; motor replacement quoted separately |
Ranges are typical for Chicago 60634, IL and confirmed with an exact written quote before any work starts.
How it works
- 1
Check fan setting
Rule out the simple thermostat setting.
- 2
Watch burner cycle
See whether the burners light and stay lit.
- 3
Written quote
Price in writing before work.
- 4
Test
Confirm warm air at the vents.